4.5.2 Read Event Status Register
This query reads the Event Status Register (ESR). After reading the ESR, the register is cleared.
The bit configuration of the ESR is the same as the Event Status Enable Register (*ESE). The
return parameter is weighted as shown in Table 4.6.
The Power On Bit (PON) is set every time the power supply is reset. It can be used to detect a
power outage or power supply reset.
Query Syntax: *ESR?
Example: *ESR?
Return Parameter: <NR1> (Register value)
Related Commands: *CLS, *ESE, *ESE?